Home
Editorial Boards
Author Guide
Editor Guide
Reviewer Guide
Published Issues
journal menu
Aims and Scope
Article Processing Charge
Indexing Service
Open Access
Publication Ethics
Editorial Process
Contact Us
Copyright and Licensing
General Information
ISSN:
2315-4462 (Print); 2373-3594 (Online)
Abbreviated Title:
Int. J Smart Grid Clean Energy
Frequency:
Quarterly
Editor-in-Chief:
Prof. Danny Sutanto
Managing Editor:
Ms Jennifer Zeng
DOI:
10.12720/sgce
APC:
500 USD
Indexed by:
Inspec (IET),
CNKI
, Google Scholar,
etc
.
E-mail:
editor@ijsgce.com
Editor-in-Chief
Prof. Danny Sutanto
University of Wollongong, Australia
I am very excited to serve as the first Editor-in-Chief of the Journal of Smart Grid and Clean Energy (IJSGCE)and hope that the publication can enrich the readers’ experience .... [
Read More
]
What's New
2024-11-27
IJSGCE opened Online Submission System.
2024-11-27
IJSGCE Vol. 11, No. 5 has been published online!
2024-03-28
March 28th, 2024 News! Vol. 13, No. 1 has been published online!
Home
>
Published Issues
>
2018
>
Vol. 7, No. 4, October 2018
>
A novel control strategy for power conditioning unit to enhance power quality during FRT
Author(s):Nishij G. Kulkarni
a*
, Vasudeo B. Virulkar
b
a
Department of EE, M.B.E.S.College of Engineering, Ambajogai, 431517 India
b
Department of EE,Government College of Engineering,Chandrapur, 442403 India
International Journal of Smart Grid and Clean Energy
, vol. 7, no. 4, October 2018: pp. 257-264
ISSN: 2315-4462 (Print)
ISSN: 2373-3594 (Online)
Digital Object Identifier: 10.12720/sgce.7.4.257-264
Abstract
: This paper proposes a novel control strategy for power conditioning unit (PCU) to enhance power quality during fault ride through (FRT) operation. During unsymmetrical fault condition, PCU injects sinusoidal currents by adopting control method suggested. By using effective current limitation technique suggested here, injected currents can be limited to their rated value during a fault. To avoid triggering of overcurrent protection, FRT operation is ensured. In case of failure of dc-dc unit to handle the maximum PV power, a non-maximum power point tracking (Non-MPPT) operation mode is proposed to get it operated under severe fault condition.
Keywords
: DC link voltage control, power conditioning unit, current limitation, fault ride through
Full Paper.pdf
PREVIOUS PAPER
Control strategy of electric vehicle access to the power grid based on vehicle-to-grid
NEXT PAPER
Development of high-efficiency axial flow fan using the FANDAS code