Home
Editorial Boards
Author Guide
Editor Guide
Reviewer Guide
Published Issues
journal menu
Aims and Scope
Article Processing Charge
Indexing Service
Open Access
Publication Ethics
Editorial Process
Contact Us
Copyright and Licensing
General Information
ISSN:
2315-4462 (Print); 2373-3594 (Online)
Abbreviated Title:
Int. J Smart Grid Clean Energy
Frequency:
4 issues per year
Editor-in-Chief:
Prof. Danny Sutanto
DOI:
10.12720/sgce
APC:
500 USD
Indexed by:
Inspec (IET),
CNKI
, Crossref, Google Scholar,
etc
.
Editor-in-Chief
Prof. Danny Sutanto
University of Wollongong, Australia
I am very excited to serve as the first Editor-in-Chief of the Journal of Smart Grid and Clean Energy (IJSGCE)and hope that the publication can enrich the readers’ experience .... [
Read More
]
What's New
2024-03-28
March 28th, 2024 News! Vol. 13, No. 1 has been published online!
2024-01-04
IJSGCE will adopt Article-by-Article Work Flow. For the quarterly journal, each issue will be released at the end of the issue month.
2023-10-09
October 9th, 2023 News! Vol. 11, No. 4 has been published online!
Home
>
Published Issues
>
2019
>
Vol. 8, No. 4, July 2019
>
Detectability analysis of open phase condition in Korea’s standard nuclear power plant
Author(s): S H Hwang
a
, B H Kim
a
, S H Joung
b
, and H S Jang
b
a
Power Economics Lab, Hongik University, Seoul, Republic of Korea
b
Control & Electrical System, Korea Institute of Nuclear Safety (KINS), Daejeon, Republic of Korea
International Journal of Smart Grid and Clean Energy
, vol. 8, no. 4, July 2019: pp. 443-452
ISSN: 2315-4462 (Print)
ISSN: 2373-3594 (Online)
Digital Object Identifier: 10.12720/sgce.8.4.443-452
Abstract
: Currently, Open Phase Condition (OPC) on nuclear power system has been reported from various countries of the world and many nuclear regulatory agencies such as NRC require establishing a protective system of the power system that automatically detects the occurrence of OPC. Therefore, it is necessary to analyze the design suitability of protection system for OPC in Korean nuclear plant also. In this paper, the OPC for Korean standard nuclear plants is conspired using power system analysis program, ETAP and the detectability of protecting relay is analyzed.
Keywords
: Open Phase Condition (OPC), Fault Detection, Protection, ETAP
Full Paper.pdf
PREVIOUS PAPER
Simple payback time of semi-flexible monocrystalline silicon solar panel used for solar vehicles
NEXT PAPER
Intelligent connection of a hybrid generator (PV/Wind) to low-voltage electric grid