Home
Editorial Boards
Author Guide
Editor Guide
Reviewer Guide
Published Issues
journal menu
Aims and Scope
Article Processing Charge
Indexing Service
Open Access
Publication Ethics
Editorial Process
Contact Us
Copyright and Licensing
General Information
ISSN:
2315-4462 (Print); 2373-3594 (Online)
Abbreviated Title:
Int. J Smart Grid Clean Energy
Frequency:
Semi-annual
Editor-in-Chief:
Prof. Danny Sutanto
Managing Editor:
Ms Jennifer Zeng
DOI:
10.12720/sgce
APC:
500 USD
Indexed by:
Inspec (IET),
CNKI
, Google Scholar,
etc
.
E-mail:
editor@ijsgce.com
Editor-in-Chief
Prof. Danny Sutanto
University of Wollongong, Australia
I am very excited to serve as the first Editor-in-Chief of the Journal of Smart Grid and Clean Energy (IJSGCE)and hope that the publication can enrich the readers’ experience .... [
Read More
]
What's New
2025-09-11
A full waiver of Article Processing Charges (APC) for articles accepted until December 31, 2026
2025-12-04
IJSGCE Vol. 14, No. 2 has been published online!
2025-07-31
IJSGCE is calling for papers, please submit your paper via Online OJS Submission System
Home
>
Published Issues
>
2019
>
Vol. 8, No. 3, May 2019
>
The study on wavelet coefficient behavior of simultaneous fault on the hybrid between overhead and underground distribution system
Author(s): Chaichan Pothisarn , Chaiyan Jettanasen
Faculty of Engineering, King Mongkut’s Institute of Technology Ladkrabang, Bangkok, Thailand
International Journal of Smart Grid and Clean Energy
, vol. 8, no. 3, May 2019: pp. 367-371
ISSN: 2315-4462 (Print)
ISSN: 2373-3594 (Online)
Digital Object Identifier: 10.12720/sgce.8.3.367-371
Abstract
: This paper proposed the study on behaviour and characteristic of wavelet coefficient in case of simultaneous fault occurrence on hybrid transmission system. The ATP/EMTP software has been used to simulate 115-km hybrid transmission line that modelled after on part of PEA distribution system. The case study system is 40 km distribution line with overhead line on first 20 km section and underground cable on the second half. The Discrete Wavelet Transform (DWT) has been used to analyse fault signal. Various factor that can affect system characteristic such as inception angle, location, and type of fault has been taken into consideration. The result shown the significant change in coefficient of high frequency component when simultaneous fault occurs compared to single fault especially in hybrid distribution system when fault occur on both overhead and underground cable, thus result in problematic analysis of coefficient and complexity in design suitable algorithm. This change in system characteristic must be taken into consideration when develop protection system in order to achieve the satisfactory performance with even more complex power system in the future.
Keywords
: Distribution System, Fault, Overhead line, Underground cable, Wavelet transform
Full Paper.pdf
PREVIOUS PAPER
Pump as turbine for small-hydropower generation a solution to Africa’S energy
NEXT PAPER
Optimal power flow for power system interconnection considering wind power plants intermittency