Home
Editorial Boards
Author Guide
Editor Guide
Reviewer Guide
Published Issues
journal menu
Aims and Scope
Article Processing Charge
Indexing Service
Open Access
Publication Ethics
Editorial Process
Copyright and Licensing
Contact Us
General Information
ISSN:
2315-4462 (Print); 2373-3594 (Online)
Abbreviated Title:
Int. J Smart Grid Clean Energy
Frequency:
4 issues per year
Editor-in-Chief:
Prof. Danny Sutanto
DOI:
10.12720/sgce
Indexed by:
Inspec (IET),
CNKI
, Crossref, Google Scholar,
etc
.
Editor-in-Chief
Prof. Danny Sutanto
University of Wollongong, Australia
I am very excited to serve as the first Editor-in-Chief of the Journal of Smart Grid and Clean Energy (IJSGCE)and hope that the publication can enrich the readers’ experience .... [
Read More
]
What's New
2024-03-28
March 28th, 2024 News! Vol. 13, No. 1 has been published online!
2024-01-04
IJSGCE will adopt Article-by-Article Work Flow. For the quarterly journal, each issue will be released at the end of the issue month.
2023-10-09
October 9th, 2023 News! Vol. 11, No. 4 has been published online!
Home
>
Published Issues
>
2015
>
Vol. 4, No. 1, January 2015
>
Analysis and compensation of active power measurement error caused by non-integer period sampling
Author(s): Hui Peng
a
, Yan-Jie Song
a*
, Shao-Teng Li
b
a
Wuhan University, Wuhan 430072, China
b
State Grid Zhejiang Electric Power Company, Electric Power Research institute, Hangzhou 310014, China
International Journal of Smart Grid and Clean Energy
, vol. 4, no. 1, January 2015: pp. 65-71
ISSN: 2315-4462 (Print)
ISSN: 2373-3594 (Online)
Digital Object Identifier: 10.12720/sgce.4.1.65-71
Abstract
: A software compensation method is proposed in this paper to reduce the active power measurement error which is caused by non-integer period sampling in the electrical energy measurement process. In the process of electrical energy measurement, the sampling frequency is fixed, and it is an integer multiple of the standard frequency. When the grid frequency fluctuates, the real-time frequency deviates from the standard frequency, therefore, the sampling rate is not strictly the integer multiple of the grid frequency, which may leads to active power error. In this paper, we firstly calculate the analytic equation of active power error in non-integer period sampling, which includes the theory value and the error value, then the active power value of integral period sampling can be obtained by subtracting the error part. Finally, the MATLAB simulation shows the correction and effective of the compensation method, and it can significantly improve the accuracy of energy measurement.
Keywords
: Active power, non-integer period sampling, error compensation, real-time frequency